CONTROL QUESTIONS
Completion requirements
1) What materials are most commonly used for compressed hydrogen storage tanks (steel or composite materials)?
2) What is the purpose of the compressor in a hydrogen filling station? (compresses the hydrogen from the tank to a high pressure, which will then be fed into the vehicle)
3) List at least four functions that must be ensured by the filling station (sufficiently fast gas flow, safe disconnection and depressurization, communication between the dispensing device and the filled vehicle, no confusion of filling pressures)